18. Troubleshooting

By purchasing this DMX controller, you have acquired a product designed to the state of the art and ope-
rationally reliable. Nevertheless, problems or errors may occur. Therefore, we would like to describe how
to eliminate possible errors here:
Always observe the safety information!
Device does not work after the POWER switch (16) was switched on
• The mains unit is not plugged into the socket correctly.
• The mains unit connection line is properly connected to the device's DC INPUT port (15).
• The mains socket is not supplied with current.
The connected effect lights do not work
• Black-out mode is active, and the LED next to the BLACK OUT/DEL button (6) flashes.
• The DMX addresses are set incorrectly.
• The connection between the DMX controller and the connected effect lights is interrupted.
• The DMX line is too long or subject to interference. Use a special DMX high frequency line.
The sound to light control does not work
• Sound to light control is deactivated. Push the button RUN MODE/SWAP (7) repeatedly until the
LED MUSIC lights up in the operating mode display (8).
• The running light function is not activated (see chapter „Calling running light functions").
• Music playback volume is set too low. Try increasing volume or adjust the microphone sensitivity as
described in chapter „Calling Running Light Functions".