INSTALLATION
General
Sneeze Guards are shipped with some components pre-
assembled. Care should be taken when unpacking the shipping
carton to avoid damage to unit and components enclosed.
NOTE: To prevent delay in obtaining warranty coverage,
complete online warranty registration. See the
ImPORTaNT OWNER INFORmaTION section for
details.
SGPT Model Installation
NOTE: Remove tape and protective packaging from the
surfaces of the unit.
1. Secure the base support to the bottom channel of the two
legs using the supplied screws.
• The base support can be installed on either side of leg.
• Remove the base plugs and install on opposite side, if
necessary.
2. Secure the two posts to the base using the supplied screws.
• The posts can be installed on middle or end of leg.
• Remove the leg plugs and install on opposite side, if
necessary.
3. Slide the side glass clamp then the sneeze guard mount
onto each post.
4. Slide the angle adjustment pins through the spacer and into
the sneeze guard mount holes. Repeat on opposite post.
Glass
Bushing
Knob
Glass Mounting
Bracket
Angle Adjustment
Spacer
Knob
Post
Leg Plug
Leg
Base
Support
Leg Plug
Screw
Base Support Screw
SGPT model Installation
5. Slide the glass mounting bracket through the angle
adjustment pins. make sure both brackets are inserted into
the pins the same way to ensure both sides are angled
properly for a correct fit. The unit is designed for a 60° angle.
6. Secure the glass mounting bracket into place by tightening
the knob into the post.
7. Secure the top glass sneeze guard.
a. Insert the mounting bolt through the glass sneeze guard.
b. Place a glass bushing between the glass sneeze guard
and the glass mounting bracket.
c. Screw the mounting bolt into the glass mounting bracket.
d. Repeat on three remaining glass sneeze guard holes.
8. move the sneeze guard mounts to the desired position and
secure to the post using the knob. The bottom edge of the
top glass must be 52" (1321 mm) or less above floor.
9. Secure the side glass to the outside of each post.
a. Tighten the short knob through the glass and into the
sneeze guard mount towards the top.
b. Place a glass bushing between side glass and post.
c. Hold the side glass clamp onto the post.
d. Tighten the long knob into the bottom hole through the
glass bushing and into the clamp.
e. Repeat this step on the opposite end.
10. Place the unit in the desired location.
Mounting Bolt
Angle Adjustment
Pins
Sneeze Guard
Mount
Side
Glass
Clamp
Glass
Bushing
Base
Plug
Base Plug Screw
Post Screw
6
English
Short
Knob
Long
Knob
Form No. SGm-0815