INSTALLATION
General
Gas Griddles are shipped with most components installed and
ready for operation. Care should be taken when unpacking
the shipping carton to avoid damage to the unit. The following
installation procedure must be performed before operating the
unit.
WARNING
FIRE OR EXPLOSION HAZARD:
• This unit is designed to be used with propane or natural
gas. Contact a qualified installer to determine and
perform proper gas connections.
• Unit must be installed by qualified, trained gas
equipment installers. Installation must conform to all
local plumbing and gasfitting codes. Installation by
unqualified personnel will void the unit warranty and
may lead to fire or explosion causing property damage,
personal injury, or death. Check with local plumbing
inspectors for proper procedures and codes.
• In the absence of local plumbing and gasfitting codes,
installation must conform with National Fuel Gas Code
ANSI Z223.1/NFPA 54 or National Gas and Propane
Installation Code CSA B149.1, as applicable.
• The gas used with this unit must be the type specified
on the specification plate on this unit. To avoid personal
injury or damage to the unit, never use any other than
the specified gas.
• Unit must be connected to gas supply using a moveable
gas connector that complies with current and local
standards and codes.
• Do not twist moveable gas connector.
• Keep moveable gas connector away from hot
appliances and surfaces.
• The unit and its gas connections must be leak tested
before placing unit in operation. Use soapy water or
commercially available fluid for leak test. DO NOT use
open flame to test for leaks.
• Locate unit a minimum of 39" (100 cm) from combustible
surfaces. If safe distances are not maintained,
discoloration or combustion could occur.
• Do not install unit above or around combustible
surfaces. Discoloration or combustion could occur.
Unit must be installed in non-combustible surroundings
only.
• Do not obstruct air ventilation openings on unit. Unit
combustion or malfunction may occur.
• If the information in these instructions is not followed
exactly, fire or explosion may result causing property
damage, personal injury, or death
Unit must be installed in location with sufficient ventilation
to prevent buildup of unsafe levels of noxious fumes.
Unit must be installed on a fixed worktop. Do not install on
a moveable cart.
Unit is not weatherproof.
1. Inspect the shipping carton for obvious signs of transit
damage. If damaged, inform the freight company
immediately. CAUTION! Stop! Do not attempt to use
unit if damaged. Contact Hatco for assistance.
2. Remove the unit and any loose components/accessories
from the shipping carton. The following loose components
are included in every Gas Griddle:
• Legs
• Drip Tray
• Propane Conversion Components
• Pressure Regulator
• Gas Shut-Off Valve
NOTE: To prevent delay in obtaining warranty coverage,
complete online warranty registration. See the
IMPORTANT OWNER INFORMATION section for
details.
3. Remove tape and protective packaging from all surfaces
of the unit.
• Make sure to remove all protective film from the stainless
steel surfaces.
4. Inspect the unit for freight damage such as dents in
housing or broken knobs. If damaged, inform the freight
company immediately.
5. Install the included legs.
a. Carefully tip the unit backwards and rest it on top of
cardboard on a flat surface.
b. At each corner, thread a leg into the bottom of the unit.
Hand-tighten until snug. Do not over-tighten.
c. Return the unit to the upright position.
NOTE: The feet on the legs are adjustable for leveling the unit.
Make leveling adjustments once the unit is placed in its
final position.
Leg
Adju able Foot
Installing the Legs
Locate unit at proper counter height in an area that is
convenient for use. Location should be level and strong
enough to support weight of unit and contents.