2.3. Correct use
This device most only be used for the dry cleaning of female cattle in pens. These include cattle / cows with close-fitting
collars and trimmed tail hairs. (< 5 cm)
The regulations set out in these operating instructions must be complied with. Use of the device in any other area
shall be deemed incorrect use. The manufacturer accepts no liability for any resulting physical and/or material damage.
For the purposes of the warranty, correct use is deemed to involve operation of the machine with a maximum of
60 animals.
3. Assembly & commissioning
3.1. Supplied package
The machine is delivered on a pallet, max. 6 pieces per pallet.
• Pre-mounted brush head with wired control module
• Support arm
• Brush unit
3.2. Checking before commissioning
Before commissioning the "Swing" cow cleaning station, it must always be checked for completeness, visible defects or
sources of danger.
The following checking measures should be carried out:
• check the machine for loose or hanging parts or damage sustained during transport.
• check the cable insulation
• check that all safety devices are present and are in perfect working order.
• check whether there are any sources of danger near the machine that could impair the problem-free and safe
operation of the machine (water hoses, influence of weather, hanging cables or ropes, etc.).
3.3. Assembly
The best possible positioning and stable securing is particularly important for ensuring the problem-free operation of this
heavy-duty machine. The following must be noted:
• do not set up the machine in a confined space in the pen.
• to avoid backlogs, do not set up the machine directly before or after the milking station.
• do not set up the machine in proximity to equipment that is sensitive to dust
• mount the electrical control box on a stable, vibration-free base to avoid damage to electronic parts caused by shaking
• protect the electrical control box from rain and excessive sunlight
• only mount the machine on a stable concrete wall or pillar
• the surface on which the support arm rests must be level, otherwise the frame can become twisted –> consequential
damage
• use at least 6 heavy duty M16 screws. The fastening material must be chosen appropriate to the base. (masonry,
concrete wall). Where concrete walls are used, heavy-duty anchors are usually sufficient. Where other bases are used,
always use through-bolts.
• when mounting the machine and control box outdoors, protect it with a roof against rain and snow
• only mount the machine using suitable lifting equipment (pulley, front-loader, etc.), noting the relevant accident
prevention regulations!
• secure screws to stop them working themselves loose – > use self-tapping nuts and/or thread lockers
• check securing bolts regularly and re-tighten if necessary.
• the fastening surface (masonry, concrete wall) must be free from vibration and oscillation.
Tip: secure the machine to an even, solid concrete wall. Drill through the concrete wall and screw suitable steel
counter plates or large washers onto the other side of the wall using threaded rods onto the machine's base
frame.
33