Figure 4.1: Circuit board for Swing after 2015
Trimmer R8 for setting the
maximum value for current
spikes from 0 to 12 A
Red LED DL 1:
start motor
Red LED DL 2:
Mains power is present
Figure 4.2: Circuit board for Swing up to 2015
Trimmer 22 for setting the
maximum value for current
spikes from 0 to 12 A
Operating mode:
2 OFF – Voltage 230 volts 50/60 Hz
1 OFF – Tilt sensor (white/brown/green)
ON OFF
2 ON – Voltage 110 volts 50/60 Hz
1 OFF – Tilt sensor (white/brown/green)
ON OFF
2 OFF – Voltage 230 volts 50/60 Hz
1 ON – Tilt sensor (grey/brown/black)
ON OFF
2 ON – Voltage 110 volts 50/60 Hz
1 ON – Tilt sensor (grey/brown/black)
ON OFF
Red LED DL 1:
mains power is present
36
Message display
'r' => motor rotates right
'l' => motor rotates left
'1' => alarm: overvoltage
'2' => alarm: undervoltage
'3' => alarm: control card overheated
'4' => alarm: motor disconnected
'5' => alarm: motor blocked
„6" => Check operating mode switch
„7" => Circuit board damaged
„8" => Check operating mode switch
Message display
'r' => motor rotates right
'l' => motor rotates left
'1' => alarm: overvoltage
'2' => alarm: undervoltage
'3' => alarm: control card
overheated
'4' => alarm: motor disconnected
'5' => alarm: motor blocked
Operating mode:
1 ON – Tilt sensor
(grey/brown/black)
2 OFF – Voltage 230 volts
50/60 Hz
ON
OFF
1 2