Design Information
PRODUCT DIMENSIONS
ZVC36
The custom canopg
must be sized to fit the insert
sleeve. Construct
the canopg
with an opening
that is:
26"W x 13-3/16"D
The opening must be constructed
of 3/4" thick
material to allow the sleeve locking clips to
engage.
The Supplied Liner
Front side
34-1/2"
The stainless steel liner is shipped with each hood
insert. This non-combustible
liner protects the
underside of the canopg.
Custom Liner
If gou ore not using the supplied liner, gou mug
construct
u custom non-combustible
liner. Use the
supplied
liner as o template.
The opening
must
be 26"W x 13-3/16"D.
3/4" thick moterial must
surround
the opening to ollow the sleeve locking
clips to engage. The insert sleeve inside the cabinet
should be positioned
1/2" from the rear woll so
that the center of the 8" duct is 5-1/2" from the
rear wall.
Dimensions
and Specifications
(in inches)
Outside Dimensions
The Insert Sleeve
13"
7/8':
The bottom edge of the insert sleeve hos o 7/8"
wide flange on the sides and o 1/2" wide flange on
the front and back.
Remote Location
for the Control
The control mug be removed from the hood
and installed into u wall or countertop.
A 30-ft
length of wire is supplied to accommodate
most
installations.
A blanking plate covers the opening
when the controls are removed.
The overall size of the control
is 4-1/4" wide and
2-1/4" deep.
3-11/16"
_
!
u
1 11/ 6
Control cutout
We recommend
that the cutout in granite or other
hard surfaces be mode before the countertop
is
installed.