Design Information
PRODUCT DIMENSIONS
ZVC30
Dimensions
and Specifications
(in inches)
Outside Dimensions
27-1/2"
The custom
canopg must be sized to fit the insert
sleeve. Construct
the canopy with an opening
that is:
26"W x 13-3/16"D
The opening must be constructed
of 3/4" thick
material to allow the sleeve locking clips to
engage.
The Supplied Liner
28-1/2"
Front side
.............
_,,,
The stainless steel liner is shipped with each hood
insert. This non-combustible
liner protects the
underside
of the canopg.
Custom Liner
If gou are not using the supplied liner, you may
construct
a custom non-combustible
liner. Use the
supplied liner as a template. The opening
must
be 26"W x 13-3/16"D.
3/4" thick material
must
surround
the opening to allow the sleeve locking
clips to engage. The insert sleeve inside the cabinet
should be positioned
1/2" from the rear wall so
that the center of the 8" duct is 5-1/2" from the
rear wall.
The Insert Sleeve
.... 16-3/4"
t2,,
13"
25-3/4"
"'
1/2"
The bottom
edge of the insert sleeve has a 7/8"
wide flange on the sides and a 1/2" wide flange on
the front and back.
Remote Location for the Control
The control mag be removed from the hood
and installed into a wall or countertop.
A 30-ft.
length of wire is supplied to accommodate
most
installations.
A blanking
plate covers the opening
when the controls are removed.
The overall
size of the control
is 4-I14" wide and
2-I/4"
dee _.
1-11/!6"
s-lille"
Control cutout
We recommend
that the cutout in granite or other
hard surfaces be made before the countertop
is
installed.