Function Test; Warnings; Technical Data - Truma S 3004 Instructions De Montage

Masquer les pouces Voir aussi pour S 3004:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23

Function test

The leak tightness of the gas supply line must be tested
using the pressure drop method after installation. A test
certificate (in Germany e.g. according to DVGW Work Sheet
G 607) must be issued.
Version with lighting
The sensor electronics of the lighting calibrate themselves
whenever the 12V supply voltage is applied. This can take
several seconds. Do not touch the cover during calibration.
Then test all device functions as described in the operating
instructions.
The operating instructions must be handed over to the vehicle
owner.

Warnings

The stickers enclosed with the device must be affixed by the
installer or vehicle owner in a location in the vehicle that is
clearly visible to all users! Missing stickers can be requested
from Truma.

Technical data

(determined in accordance with EN 624 or Truma test
conditions)
Type of gas
Liquid gas (propane / butane)
Operating pressure
30 mbar (see type plate)
Rated thermal output
S 3004 / S 3004 P: 3500 W
S 5004:
6000 W
Gas consumption
S 3004 / S 3004 P: 30 – 280 g/h
S 5004:
60 – 480 g/h
Additional information according to EN 624
S 3004 / S 3004 P: Q
= 4.0 kW (Hs); 290 g/h; C
n
S 5004:
Q
= 6.8 kW (Hs); 490 g/h; C
n
Destination countries
BE, BG, RO, DK, DE, EE, FI, FR, GB, GR, UK, IS, IE, IT, LV, LT,
LU, MT, NL, NO, AT, PL, PT, SE, CH, SK, SI, ES, CZ, HU, CY
Operating voltage
1.5 V (auto ignitor with battery mode)
Power consumption
225 mW (Ignition)
Weight
S 3004 / S 3004 P: approx.
S 5004:
approx.
CE product ID number
S 3004 / S 3004 P: CE-0085CM0287
S 5004:
CE-0085CM0288
Subject to technical changes.
22
; I
51
3B/P
; I
51
3B/P
10.3 kg (without fan)
17.5 kg (without fan)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

S 3004 pS 5004

Table des Matières