Operating manual
•
Position the switch «OFF».
•
After use, if the negative pole of the battery is connected to the chassis:
-
Turn the switch to OFF and disconnect the black clamp and then the red clamp.
•
In the event that the negative terminal is plugged onto the car's chassis:
-
Turn the switch to OFF, disconnect the red clamp and then the black clamp.
•
Recharge the GYSPACK PRO 800 after use (see charging section).
IN THE EVENT OF A PROBLEM
Some more modern vehicles, equipped with highly sensitive ECUs, will not start when using this product. The voltage
drop caused by the starting current can potentially trigger ECU safety devices, and prevent the vehicle from starting.
USE AS A 12 V DC POWER SUPPLY
The cigarette lighter plug is protected by an integrated 10 A circuit breaker. In the event of an overheating
due to an overcharge, the circuit breaker will stop the power supply.
This unit can be used as a 12 V DC power source for your electrical appliances such as radios, fans, power tools, cam-
corders, etc.
• Set the switch to "OFF".
• Insert the cigarette lighter cable from your electrical device into the receptacle (cable not supplied).
The output is protected by a 10 A thermal circuit breaker.
BATTERY TESTER
This device contains a built-in battery tester to view the charge status of both internal batteries. Use the test button
located on the control panel. The result is displayed on the screen: if it is between 0 and 12 V, the battery is in critical
condition. Above 12 V the battery is in a good state of charge.
PROTECTIONS
Your device has been designed with maximum protection:
• ON/OFF battery breaker protection against overvoltage when charger is connected to the mains.
• An audible alarm warns of polarity reversal in the event of an operating error.Sound alarm to alert the user in case of
polarity reversal.
• The starter is equipped with 2 x 1.80 m copper cables, ø 25 mm² with insulated 600 A clamps.
• The GYSPACK PRO 800 is equipped with two 200 A fuses.
• The fuses can be replaced by removing this protective cover.
TROUBLESHOOTING
Troubleshooting
The device beeps and the red LED is
on.
Sparks appear when the clamps
make contact with the battery termi-
nals.
The unit can not start the vehicle.
The unit can not start the vehicle. The
internal battery voltage is lower than
12V.
Translation of the original
instructions
Causes
The device detects a polarity reversal. Check the battery polarity.
The switch is set to 12 V.
Polarity reversal.
The switch is in the OFF position.
The internal battery is discharged.
Several jump start attempts without
pause between each.
The battery voltage is incorrect..
GYSPACK PRO 800
Solutions
Switch machine off before connecting
the clamps to the battery.
Check the battery polarity.
Set the switch to the ON position.
Charge the unit, and try again after
the charge is complete.
Wait 3 minutes between 2 starts. A
start must not last more than 6 sec-
onds.
Check that the battery voltage of the
vehicle is 12V.
11