Operating manual
BATTERY REPLACEMENT:
2
Product
Battery
GYSPACK PRO 800
6-SPB-25
To replace the battery :
The booster must be disconnected form the power supply.
Unscrew the back panel (10 screws) and remove it.
Once the back panel is removed, the battery front appears (illustration). Remove the positioning belt 1
The battery is connected to the GYSPACK at two points: at the + and - terminals. 2 3 To remove the battery,
remove the 2 screws that enable the connection between the battery and the GYSPACK at the terminals + and -.
When handing over a new battery, make sure that the polarity of the battery and the GYS-
PACK are matched. Terminal - on the left, terminal + on the right (illustration). Put the 2
screws and washers back on, tighten the nuts (recommended tightening torque of 4 Nm).
Place the booster's backpanel screws back on.
Translation of the original
instructions
Type
Voltage (V)
Lead acid battery
1
Capacity (Ah)
12
28
GYSPACK PRO 800
Dimensions (cm)
Battery ref
20 x 14 x 16
53140
3
13