7.5.
General data
Diameter of the pipes
Fluid viscosity
•
8026 and 8036
•
8076
Solid particle rate in the fluid
•
8026 and 8036
•
8076
Fluid temperature
•
8026
•
8036 with S030 fitting in PVC
•
8036 with S030 fitting in PP
•
8036 with S030 fitting in PVDF
less steel
1)
•
8076 with S070 fitting in aluminium
•
8076 with S070 fitting in stainless steel
10
All manuals and user guides at all-guides.com
DN06 to DN400;
For an S020 or S030 fitting, the appropriate diameter is determined using the flow
rate/DN/fluid velocity graphs: refer to the user manuals for the fittings
•
300 cSt. max.
•
Refer to the manual for the S070 fitting
≤
•
1%
•
0 %
•
-15 to +100°C; Also factor in the temperature/pressure dependency of the 8026
inserted into an S020 fitting: see fig. 7.1
•
0 to +50°C; Also factor in the temperature/pressure dependency of the 8036: see
1)
fig. 7.2
•
0 to +80°C; Also factor in the temperature/pressure dependency of the 8036: see
1)
fig. 7.2
, brass
or stain-
•
-15 to +80°C; Also factor in the temperature/pressure dependency of the 8036:
1)
1)
see fig. 7.2
•
max. +80°C
•
max. +100°C
english
Type 8026 - 8036 - 8076
Technical data