correctIon of malfunctIons

15
correctIon of MAlfunctIonS
malfunctIon
The unit will not start
Heating process/cleaning does
not start (both yellow control
lamps flash at the same time)
No coating material emerges
from the nozzle
Coating material drips from the
nozzle
Atomisation too coarse
Spray jet pulsates
26
cause
No mains voltage
Device overheated
Slider damaged or defect
Incorrect spray attachment in use
Spray attachment is not positioned
correctly on the heating station
Heating station or container contacts
are dirty
Heating station cover is not in
position
Thermal fuse in container has been
triggered
Contacts in container or heating
station are defect
Nozzle clogged
Material volume setting too low
Paint container seal damaged
No pressure build-up in container
Container empty
Ventilation hose loose/damaged
Feed tube loose
Feed tube /
feed tube filter clogged
Air vent on feed tube blocked
Diaphragm stuck
Air cap, nozzle or needle soiled
Spray attachment incorrectly
assembled
Nozzle loose
Nozzle seal worn
Nozzle worn
Needle worn
Material volume too large
Nozzle contaminated
Viscosity of coating material too high
Too little pressure build-up in
container
Air filter heavily soiled
Amount of air too low
Air hose damaged
Coating material in container running
out
Nozzle seal worn
Air filter heavily soiled
Feed tube loose
Feed tube /
feed tube filter clogged
FinishControl 6500 TS
remedy
Check
Unplug the power plug, let the device cool
down approx. 30 minutes, do not bend the
hose, check the air filter, do not cover the intake
slots
Please contact Wagner Service
Use TempSpray spray attachment
Reposition spray attachment correctly
Clean
Mount cover
Leave container to cool down for about 5
minutes
Please contact Wagner Service
Clean
Increase volume
Replace
Tighten container
Refill
Insert or replace
Insert
Clean or use another filter
Clean
Remove and clean (see section 14.2)
Clean
Assemble correctly (see section 13.1)
Tighten Union nut
Change
Change
Use new spray attachment
Reduce volume
Clean
Dilute further
Tighten container
Change (see section 14.1)
Increase volume
Check and replace if necessary
Refill
Replace
Change (see section 14.1)
Insert
Clean or use another filter