GB
correctIon of malfunctIons
15
correctIon of MAlfunctIonS
malfunctIon
The unit will not start
Heating process/cleaning does
not start (both yellow control
lamps flash at the same time)
No coating material emerges
from the nozzle
Coating material drips from the
nozzle
Atomisation too coarse
Spray jet pulsates
26
cause
•
No mains voltage
•
Device overheated
•
Slider damaged or defect
•
Incorrect spray attachment in use
•
Spray attachment is not positioned
correctly on the heating station
•
Heating station or container contacts
are dirty
•
Heating station cover is not in
position
•
Thermal fuse in container has been
triggered
•
Contacts in container or heating
station are defect
•
Nozzle clogged
•
Material volume setting too low
•
Paint container seal damaged
•
No pressure build-up in container
•
Container empty
•
Ventilation hose loose/damaged
•
Feed tube loose
•
Feed tube /
feed tube filter clogged
•
Air vent on feed tube blocked
•
Diaphragm stuck
•
Air cap, nozzle or needle soiled
•
Spray attachment incorrectly
assembled
•
Nozzle loose
•
Nozzle seal worn
•
Nozzle worn
•
Needle worn
•
Material volume too large
•
Nozzle contaminated
•
Viscosity of coating material too high
•
Too little pressure build-up in
container
•
Air filter heavily soiled
•
Amount of air too low
•
Air hose damaged
•
Coating material in container running
out
•
Nozzle seal worn
•
Air filter heavily soiled
•
Feed tube loose
•
Feed tube /
feed tube filter clogged
FinishControl 6500 TS
remedy
•
Check
•
Unplug the power plug, let the device cool
down approx. 30 minutes, do not bend the
hose, check the air filter, do not cover the intake
slots
•
Please contact Wagner Service
•
Use TempSpray spray attachment
•
Reposition spray attachment correctly
•
Clean
•
Mount cover
•
Leave container to cool down for about 5
minutes
•
Please contact Wagner Service
•
Clean
•
Increase volume
•
Replace
•
Tighten container
•
Refill
•
Insert or replace
•
Insert
•
Clean or use another filter
•
Clean
•
Remove and clean (see section 14.2)
•
Clean
•
Assemble correctly (see section 13.1)
•
Tighten Union nut
•
Change
•
Change
•
Use new spray attachment
•
Reduce volume
•
Clean
•
Dilute further
•
Tighten container
•
Change (see section 14.1)
•
Increase volume
•
Check and replace if necessary
•
Refill
•
Replace
•
Change (see section 14.1)
•
Insert
•
Clean or use another filter