MAINTENANCE
14. MAINTENANCE SCHEDULE
Maintenance that must be performed
• Release condensate
Compressor without air drier
At high air humidity
Compressors with air drier
Compressors with condensation unit :
- from filter
- from pressure vessel
• Check safety valve
• Replacement of input filter
• Replacement of filter in dryer
• Replacement of filter
in condensation unit
• Check tightness of joints
Overall examination of device
15. MAINTENANCE
Repair work beyond normal maintenance can be performed only by qualified personnel or
the manufacturer's representative.
Use only spareparts and accessories approved by the manufacturer.
Prior to any maintenance or repair work, switch off the compressor and disconnect it from
the mains (pull out the mains plug).
To ensure that the compressor works correctly, perform the following maintenance tasks at regular intervals
(Chapter 14).:
15.1.
Condensation drain valve
Compressors (Fig.12, Fig.13)
During regular use, release condensation from the pressure tank
weekly. At times of high humidity drain condensation daily. Switch off
the compressor at the mains. Reduce air pressure in the appliance to
max. 1 bar by releasing air via a connected device. Place the hose with
the drain valve into a container prepared in advance (for compressors
DK50 2V/110 and DK50 2x2V/110 orientate the vessel towards the
) and open the drain valve (1). Wait until condensation is fully
drain valve
drained from the pressure tank. Close drain valve (1).
Compressors with condensation and filtration unit (Fig.16)
During regular use, condensation is automatically released via the
release valve of the condensation unit filter.
automatic drain is working properly, open the valve (4) of the drain
vessel (2) by turning to the left.
condensate from the vessel. Close the valve (4) by turning to the right.
Compressors with air dryer
In the case of a regular operation condensate is automatically excreted
via air dryer and it is entrapped in a bottle located at the housing side.
Take out the bottle from a holder, release blowing-out suppressor and
pour out the condensate.
If necessary, it is possible to connect the set for condensate discharge onto the condensate outlet
(see Chap.5 - Auxiliary Equipment).
04/2009
All manuals and user guides at all-guides.com
Chapter
15.1
15.2
15.3
15.4
15.5
Service
documentation
To check that the
Release a small amount of
- 35 -
Time interval
1 x week
1 x day
1 x week, check function
1 x week, check function
1 x week
1 x year
1 x every 2 years
1 x year
1 x year
1 x year
Fig.13
Performed by
operating staff
operating staff
operating staff
operating staff
operating staff
qualified
technician
qualified
technician
qualified
technician
qualified
technician
qualified
technician
Fig.12
1
DK50 2V
NP-DK50 2V-2