ENGLISH
32
Inspection and maintenance plan
Repairs and works specified in these Instructions may only be performed by qualified authorised staff. Use only
original accessories and original spare parts.
Regular servicing period
Engine oil
Petrol hose
Exhaust system
Choke
Cable starter
Air filter
Petrol filter
Spark plug
Tip: To ensure reliable operation of the appliance, we strongly recommend using fuel additives and performing
2-3 test operations after a longer time of not using the unit.
Failure removal
Failures
The motor does not start.
Engine running irre-
gularly
Before any
start-up
Inspection
Change
Inspection
Clean
Change
Clean
Inspection
Clean
Causes
Closed fuel tap
Lack of fuel
Weak tension on the starter
Wrong fuel, storing without petrol tank
being drained
Sooted spark plug (carbon residues on
electrodes), electrodes distance too big
The spark plug is wet from petrol (over-
saturated engine).
Little oil in the engine
Unit is not in a horizontal position. Lack
of oil being signalled
Choke has not been used
Problem with ignition
Wrong fuel (propellant)
After 1 month
After 3
or 20 hours of
months or
operation
50 hours of
operation
Removal
Make sure the fuel tap and On/Off are in
the „ON" position
Add some fuel
Pull strongly the starting cord.
Drain the fuel tank and carburettor, add
fresh petrol
Clean the spark plug, check the plug
thermal value, possibly change the
plug, set the electrodes distance to
0.6-0.7 mm
Dry the spark plug out and refit it.
Add oil
Place the unit in a horizontal position
Use the choke
Make sure the spark plug is fitted pro-
perly. Make sure the spark plug cable is
on the spark plug. Clean the spark plug
and check the electrodes if correct.
Make sure proper fuel has been used.
After 6
After 200
months or
hours of
100 hours of
operation
operation