5.2.1
SUM OF PARTIAL COUNTERS
This screen displays the sum of the partial doses (resettable)
dispensed. The sum considers each dose 2 as twice dose 1
and each dose 3 as three times dose 1. For example, if 5 x
dose 1, 5 x dose 2 and 5 x dose 3 have been dispensed, the
sum will be 30. The RESET button, if pressed for a long time,
resets the counters.
5.2.2
EXTRA DOSE ADJUSTMENT
This screen is used to set the extra dose time (D) from a
minimum of 0.2 second to a maximum of 1 second.
Press the "+" and "-" buttons to increase or decrease the time.
5.2.3
PASSWORD
This screen allows setting the password for the appliance. When enabled, the
password will be needed to access the technical menu, to lock/unlock the dose
adjustment as well as to disable the password itself.
• ON: password enabled.
• OFF: password disabled.
To set the password, press ON and then enter a 4-digit code. After pressing the
CONFIRM key, re-enter the password and then press SAVE. To change the password,
press SET.
It is necessary to enter the previously set password first; by pressing the NEXT key it
will be possible to enter and confirm the new password..
PASSWORD
NEW PASSWORD
CONFIRM
CONFIRM
PASSWORD
SAVE
PARTIAL
COUNTERS
1
0000
2
0000
3
0000
0000s
M
RESET
EXTRA DOSE
SETTING
PASSWORD
SETTING
33