Device Informa-
Used to display settings relevant to a power supply company. The displayed values de-
tion
pend on the respective country setup or device-specific inverter settings.
Display range
General:
Country Setup:
MPP Tracker:
AC Monitoring:
AC Voltage Limits:
AC Frequency Limits:
Q-Mode:
General/Country Setup/MPP Tracker/AC Monitoring/AC Volt-
age Limits/AC Frequency Limits/Q-Mode/AC Power Limits/AC
Voltage Derating
Device type
Fam.
Setup
Country setup used
Version
Country setup version
Group
Inverter software update group
Tracker 1 (status, voltage)
Tracker 2 (status, voltage)
GMTi
Startup time of the inverter in s
GMTr
Restart time in s after a grid error
ULL
Grid voltage average value over 10 minutes in V.
LLTrip
Detection time for long-term voltage monitoring
UILmax
Upper inner grid voltage value in V
UILmin
Lower inner grid voltage value in V
UOLmax
Upper outer grid voltage value in V
UOLmin
Lower outer grid voltage value in V
FILmax
Upper inner grid frequency value in Hz
FILmin
Lower inner grid frequency value in Hz
FOLmax
Upper outer grid frequency value in Hz
FOLmin
Lower outer grid frequency value in Hz
Currently set power factor (cos phi)
(e.g., Constant Cos(phi)/Constant Q/Q(U) characteristic/etc.)
33