Télécharger Imprimer la page

Clock 06 - Wordclock B; Clock 07 - Wordclock C; Clock 08 - Wordclock D; Clock 09 - Aes 1/Aes 2 Output - Steinberg NEUNDO SyncStation Mode D'emploi

Publicité

Les langues disponibles

Les langues disponibles

>1x
When set to 1x, the word clock output signal is generated
by the SyncStation and referenced to the chosen clock ref-
erence. It will run at the rate set in "Clock 02 - Clock Rate".
>2x
The 2x setting multiplies the master clock rate in the Sync-
Station to output a rate twice as fast. If the clock rate is set
to 48kHz, the word clock output would run at 96kHz for
example.
>4x
The 4x setting allows word clock output rates up to
192kHz.
>256x
The 256x multiplier is a special use for synchronizing
Digidesign hardware units that use this proprietary word
clock signal.

Clock 06 - Wordclock B

Settings for the second word clock output.

Clock 07 - Wordclock C

Settings for the third word clock output.

Clock 08 - Wordclock D

Settings for the fourth word clock output.
Changing the word clock output in Nuendo
In Nuendo's Project Synchronization Setup dialog, click
the "Open SyncStation Settings" button to access the
word clock output settings.
SyncStation Settings pop-up window with "Word Clock Output"
setting menu
All four word clock outputs can be linked together so that
changing the setting of one output affects all others in the
same way.
Word clock output link

Clock 09 - AES 1/AES 2 Output

Clock 09-AES1/AES2 Output
>Clk Ref I/P >Slink I/P >1x Clk >2x Clk
The two AES outputs can be set to follow the clock refer-
ence input, the System Link input or the internal generator
running at 1x or 2x rates.
>Clk Ref I/P (Clock Reference)
The AES clock will be generated from the clock reference
input as set in menu Clock 01.
>Slink I/P (System Link Input)
The AES clock will be generated from the System Link in-
put set in menu Unit 05. The extended System Link does
not have to be active in the SyncStation. However, other
System Link signals will be passed from the AES inputs to
the outputs so that normal System Link operation is possi-
ble through the SyncStation.
>1x Clk (Clock)
The AES output will be generated by the SyncStation at
the master clock rate.
>2x Clk (Clock)
The AES output will run at twice the master clock rate.
29
Menu Reference

Publicité

loading