Timer Mode Example: It might be helpful to think of Timer Mode in the form of a 24 hour or clock timeline . If you want your pet(s) to have full
access during the daytime (for example, from 7 am in the morning until the late evening) but want your pet(s) to be indoors at night (for example,
starting at 7 pm), you would want to set the access mode to In/Out at 7 am and then the access mode to In-Only at 7 pm .
12 am
In-Only
In/Out
To Remove Timer Mode Access Time:
1 . From Main Menu select Setup > Pet Settings > Master Access > Mode .
2 . Press right arrow key to scroll to Timer option to select .
3 . Once Timer has been selected, Access Time will appear at bottom of
Master Access Menu list . Use down arrow key to highlight Access
Time then right arrow key to select .
4 . Use up and down arrow keys to highlight which Access Time slot you
wish to remove . Press right arrow key to select .
5 . Use down arrow key to highlight Remove and right arrow key to
select . The time slot on the Access Time Menu should now be removed .
Remember you must have a minimum of two programmed
Access Times for Timer Mode to work .
Note: Timer Mode can be disabled by setting a different Master Access Mode, while keeping the programmed Timer Mode Settings . This might be
useful if you want to use Timer Mode during the week and a different Master Access Mode on the weekend .

Re-latch Time (Master Access)

The Re-latch Time is the amount of time it takes the Dog Door flap to re-lock after the Passport
same Re-latch Time is easily set for all pets . The factory default Re-latch Time is set to 2 seconds but can be changed from 1 second to 60 seconds .
A longer Re-latch Time may be needed if you have older or slower pets .
To Change Re-latch Time:
1 . From Main Menu select Setup > Pet Settings > Master Access . Use right arrow key to select .
2 . Use down arrow key to highlight Re-latch Time then use right arrow key to scroll through to find desired
Re-latch Time . Press left arrow/back key to return to Main Menu .
7 am
12 pm
After using Timer Mode to program the example
listed, the Access Time menu screen would display:
www.petsafe.net
7 pm
Example:
Key is no longer detected . Under Master Access the
1 1 pm
7