FINAL OPERATIONS
Once the electrical connections are done and the set up is fi nished, fasten the cables to the gearmotor jumper
using a cable tie.
Fit the cover and fasten it to the sides using the screws.
ERROR MESSAGE
The error messages are shown on the display.
E 1
The travel calibration was interrupted when the STOP button was activated
E 2
Calibrating the complete gate-travel
E 3
Encoder broken
E 4
Services test error
E 7
Insuffi cient working time
E 8
The NC contacts are open (for example, the limit-switches)
E 9
Closing obstruction
E 10
Opening obstruction
E 11
Maximum number of detected obstructions
E 14
Serial communication error
E 17
Wireless system error
E 18
The wireless system confi guration is missing
TROUBLESHOOTING
ISSUES
It neither opens nor
closes
The gate opens but
does not close
POSSIBLE CAUSES
• Power supply is missing
• The gearmotor is stuck
• The transmitter doesn't work
• The transmitter is broken
• The stop button is either stuck or broken
• The opening/closing button or the key-switch
selector is stuck
• The wireless accessory does not work
• The photocells are dirty
FIXES
• Check main power supply
• Lock the gearmotor
• Replace the batteries
• Call for assistance
• Call for assistance
• Call for assistance
• Call for assistance
• Clean and check proper
functioning of the photocells