F37 Opening slow-down
point
Percentage adjustment of the total gate travel, of the opening slow-down starting point.
This function appears only is the Encoder function is activated.
F38 Closing slow-down point
Percentage adjustment of the total gate travel, from the closing slow-down starting point.
This function appears only is the Encoder function is activated.
F49 Managing serial connec-
tion
To enable paired operation or the Came Remote Protocol.
F50 Save data
Saving users and saved settings in memory roll.
This feature only appears if a memory roll has been fi tted into the control board.
F51 Read data
Uploading data saved in memory roll.
This feature only appears if a memory roll has been fi tted into the control board.
F52 Passing parameter in
paired mode
Uploading settings from Master to Slave.
This appears only if function F49 is set to Paired.
F54 Opening direction
For setting the gate opening direction.
F56 Peripheral number
To set the peripheral's number from 1 to 255 for each control board when you have a system with several
operators.
F63 Change COM speed
For setting the communication speed used in the CRP (Came Remote Protocol) connection system.
F65 Wireless input RIO-EDGE
[T1]
Wireless RIO-EDGE safety device associated to a function chosen among those available: P0 = total stop, P7 =
reopening during closing, P8 = reclosing during opening.
For programming, see the instructions that come with the accessory.
This function only appears is the control board has been fi tted with a RIO-CONN card.
F66 Wireless input RIO-EDGE
[T2]
Wireless RIO-EDGE safety device associated to a function chosen among those available: P0 = total stop, P7 =
reopening during closing, P8 = reclosing during opening.
For programming, see the instructions that come with the accessory.
This function only appears is the control board has been fi tted with a RIO-CONN card.
F67 Wireless input RIO-CELL
[T1]
10 = 10% of the gate travel (default) / ... / 20 = 20% of the travel
10 = 10% of the gate travel (default) / ... / 20 = 20% of the travel
OFF = Deactivated (default) / 1 = Paired / 3 = CRP
OFF = Deactivated (default) / ON = Activated
OFF = Deactivated (default) / ON = Activated
0 = Deactivated (default) / 1 = Activated
0 = Opening towards the left (default) / 1 = Opening towards the right
1 ----> 255
0 = 1200 Baud / 1 = 2400 Baud / 2 = 4800 Baud / 3 = 9600 Baud / 4 =
14400 Baud / 5 = 19200 Baud / 6 = 38400 Baud / 7 = 57600 Baud / 8
= 115200 Baud
0 = Deactivated (default) / P0 / P7 / P8
0 = Deactivated (default) / P0 / P7 / P8
0 = Deactivated / P1 (default) / P2 / P3 / P4