SAFETY DEVICES
Photocells
Confi gure contact CX or CY (NC), safety input for photocells.
See CX input functions (Function F2) or CY (Function F3) in:
- C1 reopening during closing. When the gate is closing, opening the contact triggers the inversion of movement
until the gate is fully open again;
- C2 close back up during opening. When the gate is opening, opening the contact triggers the inversion of
movement until the gate is completely closed.
- C3 partial stop. Stopping of the gate, if it is moving, with consequent automatic closing (if the automatic closing
function has been entered);
- C4 obstruction wait. Stopping of the gate, if it is moving, which resumes movement once the obstruction is
removed.
 If contacts CX and CY are not used they should be deactivated during programming.
10 TS 2 CX CY
10 TS 2 CX CY
1 2 3P 7
1 2 3P 7
FC FA F
FC
-
+
-
-
RX
TX
RX
TX
TX 2
10 2 TX C
NC
TX 2
+ - NO C
NC
+
TX 2
-
DELTA-S
DIR
DELTA
Sensitive Safety Edges
Confi gure contact CX or CY (NC), safety input for sensitive safety-edges.
See CX input functions (Function F2) or CY (Function F3) in:
- C7 reopening during closing. When the gate is closing, opening the contact triggers the inversion of movement
until the gate is fully open again;
- C8 reclosing during opening. When the gate is opening, opening the contact triggers the inversion of movement
until the gate is fully closed.
 If contacts CX and CY are not used they should be deactivated during programming.
1 2 3P 7
10 TS 2 CX CY
10 TS 2 CX CY
1 2 3P 7
10 11 E
5
DFW with control board of the
DFW
DFI connections