The Meta HPA Evo control unit automatically recognizes the siren model and adapts to it. It is recognized by a
BOOP emitted when the alarm system is powered up, so the installer must connect it before powering up the
alarm system.
M03
BLACK
BLACK/RED
INSERT
IN PIN 2
INSERT
IN PIN 14
Fig. 5
WFR
PAIRING THE SIREN WITH THE ALARM (SIREN SELF-LEARNING PROCEDURE)
Phase 1: disconnect the alarm control unit connector and insert the four pins from the module wiring. Plug the
2-way connector with the aerial lead into the module.
During phase 2, leave the alarm control unit connector DISCONNECTED.
Phase 2: power up the siren and, within 30 seconds, press the boot button connected to the siren 5 times, or if
there is no boot button connected to the siren, give 5 GND pulses on the purple wire in the siren wiring. To confi rm
that your radio module has entered the learning phase, the siren will emit a Bip Boop Bip Boop acoustic signal, and
remain in the learning phase for 3 minutes from this moment.
Phase 3: power up the alarm control unit within 3 minutes from when the siren is ready for pairing. To confi rm that
the pairing was successful, the siren will emit a Bip Beep Bip Beep acoustic signal.
ONLY USE THE CORRECT BATTERIES INDICATED IN THE INSTRUCTIONS.
CONNECTING THE SIREN
ALARM
CONTROL UNIT
CONNECTOR
CAUTION! RISK OF EXPLOSION IF THE BATTERY
IS REPLACED WITH THE INCORRECT TYPE.
15
M05
RED/BLUE
RED
BLACK
INSERT
IN PIN 2
INSERT
IN PIN 1
INSERT
IN PIN 14
INSERT
INSERT
IN PIN 1
IN PIN 2
INSERT
IN PIN 13
INSERT
IN PIN 14
ALARM
CONTROL UNIT
CONNECTOR
Fig. 6