Technical Data - Sunrise Medical DEVILBISS UltraNeb Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7. Technical data

Technical data
Ambient conditions
During operation: . . . . . . . . . . . . . . . . . . . . . . . . . . . Temperature 10° to 40° C, Humidity 0 to 90 %
During storage: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Temperature -20° to 70° C,Humidity 0 to 90 %
Performance data
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 V / 127 V / 230 V; AC, 50 to 60 Hz
Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IEC 127-T800 L 250 V, 2 EA
Power consumption: . . . . . . . . . . . . . . . . . . . . . . . Ultrasonic nebulizer 50 VA; Hose heating 30 VA
Resistance of hose heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Ohm (± 5 %)
Ultrasonic frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1,68 MHz (± 5 %)
Noise pressure level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . about 35 dB(A)
Humidity protection type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP 32 (dripping water)
Method of operation: Continuous operation
Nebulizer output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . max. 3 ml/min
Nebulizer output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . with sterile water system up to 2,5 ml/min
Droplet size (MMAD) . . . . . . . . . . . . . . . . . . . . . . . . . . average 4 μm, about 86 % lower than 5 μm
Air flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . up to 20 L/min (when using AQUA+ F or SecuRed Big)
Classification
as per EC Directive 93/42/EEC, Annex IX Class IIa
CE-Labelling
Directive 93/42/EEC concerning Medical Devices
General information on electromagnetic compatibility (EMC) according to
the international EMC standard IEC 60601-1-2: 2001
Medical electrical equipment needs special precautions regarding electromagnetic compa-
tibility (EMC) and needs to be installed and put into service according to the EMC information
provided in the technical documentation avail-able from Sunrise Medical Service upon
request.
Portable and mobile RF communications equipment can affect medical electrical equipment.
Pins of connectors identified with the ESD warning symbol shall not be touched and not be
connected unless ESD precautionary procedures are used. Such precautionary procedures
may include antistatic clothing and shoes, the touch of a ground stud before and during
connecting the pins or the use of electrically isolating and antistatic gloves. All staff involved
in the above shall receive instruction in these procedures.
Dimensions:
Height over all . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19,0 cm
Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20,5 cm
Depht . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31,5 cm
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . about 3,5 kg
relative humidity without condensation
relative humidity without condensation
English
27

Publicité

Table des Matières
loading

Table des Matières