8.2 Control panel
Warning
At high liquid temperatures, the pump
may be so hot that only the buttons
should be touched to avoid burns.
The control panel, fig. 11, incorporates:
Pos.
Description
1
Buttons for setting
• Indicator lights for operating and fault
indication and
2
• symbol for indication of external control
3
Button for change of control mode
Light symbols for indication of control
4
mode and night-time duty
Light fields for indication of head, flow and
5
operating mode
For further information, see section 9. Fault finding
chart.
Fig. 11
Control panel
ГК Водная техника info@water-technics.ru (495) 771 72 72 www.water-technics.ru
Интернет-магазин info@wtpump.ru (499) 937 50 61 (800) 505 78 67 www.wtpump.ru
8.2.1 Control mode setting
Description of function, see section 7.1 Control
modes.
To change the control mode, press
according to this cycle:
Fig. 12
Cycle of control modes
Automatic night-time duty can be activated together
with each of the control modes.
The light symbols in pos. 4, see fig. 11, indicate the
pump settings:
Light in
Control mode
AUTO
AUTO
ADAPT
Proportional
pressure
Constant pressure
Constant curve
AUTO
AUTO
ADAPT
Proportional
pressure
Constant pressure
Constant curve
"–" = no light.
, pos. 3,
Automatic
night-time
duty
NO
ADAPT
NO
NO
NO
YES
ADAPT
YES
YES
YES