Note: Measures required when the pump fails to suck water after a long time of storage
Insert a finger into the hole and depress the yellow cap for one or two pushes.
Dispensing chemicals
● Carefully read in advance the instruction sheet of the chemical to be used, and follow the specified
dispensing method and precautions for using it.
CAUTION
● When using a hydrate chemical, first dispense at its specified proportion, put it in a bucket or other
container and allow it to dissolve well before hand.
● When pouring the solution in the tank, be sure to use the strainer provided.
Starting
(1) Choose the spray mode "spot spraying" or "continuous
spraying" Grip the grip lever and start the spraying.
(2) Adjust the pressure to an appropriate level by looking at the
mist from the nozzle.
Turn the pressure regulation knob to the right to increase the
pressure or to the left to decrease it.
This product is set to the lowest pressure before shipping.
Stopping
Refer to the description on the functions of operating section
(described on page 5)
(1) When the mode select lever is set at continuous spraying
position.
Pushing the release button releases grip lever, and stops the
spraying.
(2) When the mode select lever is set at spot spraying position.
Releasing the grip lever stops the spraying.
If anything is wrong, immediately release the grip lever and stop spraying.
English
Cap
Hole
Grip lever
Continuous spraying
Mode select lever
Release button
- 7 -
Cap (yellow)
finger
Pressure regulating knob
Spot spraying