7.
Use
• Use only solvent-resistant, antistatic, undamaged and technically flaw-
less compressed air hoses with a permanent pressure resistance of
minimum 10 bar / 145 psi, e.g. Art. No. 53090!
The following requirements must be fulfilled:
• Use of a compressed air connection G 1/4 a or of a fitting SATA con-
nection nipple.
• Ensure minimum compressed air volume (air consumption) and pres-
sure (recommended spray gun inlet pressure) according to chapter 2.
• Clean compressed air, i.e. with SATA filter 100, Art. No. 148247,
outside the spray booth or SATA filter 484, Art. No. 92320 in-
side the spray booth
• Use an air hose with minimum 9 mm inner diameter (see warnings),
e.g. Art. No. 53090.
176.
Check if all screws [2-1], [2-2], [2-3], [2-4] and [2-5] have been
tightened firmly. Tighten fluid tip [2-1] firmly by hand (14 Nm) accord-
ing to [7-4]. Check if locking screw [2-5] has been firmly tightened
according to [10-1]. Tighten, if necessary.
Rinse material passages with suitable cleaning solution [2-6], ob-
177.
serve chapter 8.
178.
Adjust air cap: vertical spray fan [2-7], horizontal spray fan [2-8].
179.
Insert paint strainer [2-9] and install gravity flow cup [2-10].
180.
Fill gravity flow cup (max. 20 mm below upper edge), close with the lid
[2-11] and insert anti-drip device [2-12].
Screw connection nipple [2-13] (not included in delivery) onto the air
181.
inlet.
182.
Connect compressed air hose [2-14].
444
Danger! Risk of explosion!
Information!