Operating
MCS T6, MCS T12, MCS T16
7.3

Modes of Operation

Off Mode
When the Marine Climate System is in the Off Mode, all control outputs are turned
off. Program parameters and user settings are saved in nonvolatile memory.
On Mode
When the Marine Climate System is in the On Mode, power is supplied to the appro-
priate outputs and the display indicates the current state of operation. The operating
and program parameters resume based on those stored the last time the unit was
operating.
Cool Mode
When Cool Mode is selected, the Cool Mode LED is lit and the cooling systems are
operated as required. When the temperature drops below the set point, the system
will not automatically switch to the Heat Mode.
Heat Mode
When the Heat Mode LED is lit, only the heating systems are selected and operated
as required. Should the temperature rise above the set point, the system will not
automatically switch to the Cool Mode.
Automatic Mode
Automatic Mode provides both heating and cooling as required. The Heat or Cool
LED will be lit according to the mode required.
Temperature in a given mode is maintained within 1.1 °C (2 °F) of set point, however
a 2.2 °C (4 °F) difference is required to allow the Marine Climate System to change
modes.
Once the mode changes temperature will be maintained within 1.1 °C (2 °F) of set
point.
Manual Fan Mode
Manual Fan Mode allows to select the desired fan speed manually. When a manual
fan speed has been selected, the Fan LED will be lit. Manual Fan Mode is sometimes
preferred when room temperature is constantly changing due to varying heat loads.
The fastest fan speed is represented by "6", the slowest represented by "1".
10