7.5
Automated Factory Self Test Program
The Marine Climate System software provides a self test program to facilitate factory
testing of the entire air conditioning system. Once the self test program is activated,
the test cycle will continue until the AC power is interrupted or the Power Button is
pressed once which returns the system to the Off Mode.
➤ Activate the self test program by pressing the Power Button while turning on the
AC power.
➤ Release the Power Button while the display indicates "888" and all LEDs are lit.
✓ The Marine Climate System is now in the self test program.
✓ "tSt" appears in the display while in the self test program.
Once activated the self test software will continuously execute the following proce-
dure:
Turn on in the Heat Mode and supply heating for 10 min.
Stop heating and run the fan only for 5 min.
Switch to Cool Mode and continue cooling for 10 min.
Stop cooling and run the fan only for 5 min.
Return to step one and continue until interrupted.
The self test program will continue until the power is interrupted or the test is halted
by pressing the Power Button once.