In contrast to the bridge card, the UA-OFF monitoring board has to be taken into
account when configuring the control.
12.2.9 Possible combinations of base plates and cards
Valve driver boards, 4x, are always combined with two 2x base plates.
Table 24 shows the possible combinations of base plates, pneumatic supply
plates, electrical supply plates, and transition plates with various valve driver
boards, bridge cards, and supply boards.
Table 22: Possible combinations of plates and cards
Base plate
Base plate, 2x
Base plate, 3x
Two base plates, 2x
Pneumatic supply plate
Transition plate and pneumatic supply plate
Electrical supply plate
The boards in the AV-EP base plates are installed permanently and can
therefore not be combined with other base plates.
12.3 Identifying the Modules
12.3.1 Material number for bus coupler
The bus coupler can be clearly identified using its material number. When ex-
changing the bus coupler, you can use the material number to reorder the same
unit.
The material number is printed on the name plate (12) on the back of the device
and on the top below the identification key.
12
AES-D-BC-XXXX
R4120XXXXX
12.3.2 Material number for valve system
The material number for the complete valve system (46) is printed on the right
end plate. You can use this material number to reorder an identically configured
valve system.
Note that, after a valve system conversion, the material number still refers to
u
the original configuration g 12.5.5. Conversion documentation.
AVENTICS™ EtherNet/IP | R412018139-BAL-001-AG | English
Circuit boards
Valve driver board, 2x
Valve driver board, 3x
Valve driver board, 4x
Short bridge card or
UA-OFF monitoring board
Long bridge card
Supply board
7291
46
12.3.3 Identification key for bus coupler
The identification key (1) on the top of the AES series bus coupler for EtherNet/IP
is "AES-D-BC-EIP" and describes the unit's main characteristics.
12.3.4 Equipment identification for bus coupler
The bus coupler requires a unique ID to enable the clear identification of the unit
within the system. The two equipment identification fields (4) on the top and
front of the bus coupler are available for this purpose.
Label the two fields as shown in your system diagram.
u
12.3.5 Bus coupler rating plate
The rating plate is located on the back of the bus coupler. It contains the follow-
ing information:
47
48
AES-D-BC-XXXX
49
R4120XXXXX
50
51
52
53
54
55
Fig. 16: Bus coupler rating plate
47
Logo
49
Mat. no.
51
Power supply
53
Serial number
56
Data Matrix code
58
Internal plant ID
1
4
58
57
7291
56
48
Series
50
MAC address
52
Manufacture date (FD) with format
"FD: <YY>W<WW>"
55
Country of manufacture
57
CE mark