Télécharger Imprimer la page

DAB PULSAR Serie Instructions De Mise En Service Et D'entretien page 30

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
13.
TROUBLESHOOTING
FAULT
1. The motor does not start
and makes no noise.
2. The
pump
does
not
deliver.
3. The pump does not stop.
4. The
flow
rate
insufficient
5. The overload protection
device stops the pump.
Pumpland.ru
ENGLISH
CHECK (possible cause)
A. Check that the motor is live and that the
mains voltage corresponds to the voltage
on the data plate.
B. Check the protection fuses.
C. The float switch does not allow starting.
D. The shaft is not turning.
A. The suction filter or the pipes are
blocked.
B. The impellers are worn or blocked.
C. The check valve, if installed on the
delivery pipe, is blocked in closed
position.
D. The fluid level is too low. On starting,
the water level must be higher than the
filter level.
E. The head required is higher than the
pump's characteristics.
F. In the PULSAR DRY versions the pump
is not primed.
A. The float does not interrupt pump
operation.
is
A. Check that the suction filter is not
partially clogged in PULSAR pumps.
B. Ensure that the impellers or the delivery
pipe are not partly blocked or fouled
with scale.
C. Ensure that the impellers are not worn.
D. Ensure that the check valve (if fitted) is
not partly clogged.
E. Check the direction of rotation in three-
phase versions ( See Chapter on Electrical
connection - Paragraph 8.4. ).
A. Ensure that the fluid to be pumped is not
too dense because it would cause
overheating of the motor.
B. Ensure that the water temperature is not
too high (see liquid temperature range).
C. The
pump
is
impurities..
D. The pump is mechanically blocked.
B. If they are burnt-out, change
C. Check that the float moves
D. Turn the shaft as indicated in
A. Remove the obstructions, as
B. Change the impellers or remove
C. Check good operation of the
D. Regulate the length of the float
F. Prime the pump. (See Fig.2).
A. Check that the float moves
A. Remove any obstructions, as
B. Remove any obstructions.
C. Change the impellers.
D. Accurately clean the check
E. Invert two wires in the power
partly
blocked
by
C. Accurately clean the pump.
D. Check for the occurrence of
27
REMEDY
them.
freely and that it is efficient.
the
chapter
on
Warnings
(Paragraph 6.3./6.4 ).
indicated in the chapter on
Warnings (Paragraph 6.5.).
the obstruction.
valve and replace it if necessary.
switch cable (See chapter on
Warnings – Paragraph 9.3.).
freely and that it is efficient.
indicated in the chapter on
Warnings (Paragraph 6.5. ).
valve.
cable.
rubbing between moving and
fixed parts; check the state of
wear of the bearings (contact
the supplier).

Publicité

loading