PUMPED FLUIDS
The machine has been designed and built for pumping water, free from explosive
substances and solid particles or fibres, with a density of 1000 kg/m³ and a kinematic
viscosity of 1 mm²/s, and chemically non-aggressive liquids.
4.
TECHNICAL DATA AND RANGE OF USE
Supply voltage:
Absorbed power:
Head up – Hmax (m):
Maximum working pressure:
Pumped fluid:
Degree of motor protection:
Thermal class:
Line fuses class:
PULSAR – PULSAR DRY 30/50
PULSAR – PULSAR DRY 40/50 – 40/506
PULSAR – PULSAR DRY 50/50 – 50/506
PULSAR – PULSAR DRY 65/50 – 65/506
PULSAR DRY 20/80
PULSAR – PULSAR DRY 30/80 – 30/806
PULSAR – PULSAR DRY 40/80 – 40/806
PULSAR – PULSAR DRY 50/80 – 50/806
Liquid temperature range:
Maximum immersion PULSAR: 20 metres
Storage temperature:
Noise level:
Motor constructions:
5.
MANAGEMENT
5.1.
Storage
All the pumps must be stored indoors, in a dry, vibration-free and dust-free environment, possibly with
constant air humidity.
They are supplied in their original packaging and must remain there until the time of installation.
5.2.
Transport
Avoid subjecting the products to needless jolts or collisions.
The electropumps must never be carried or lifted by their power cables.
5.3.
Weight
The adhesive label on the package indicates the total weight of the electropump.
Pumpland.ru
ENGLISH
see electric data plate
see electric data plate
pag. 109
10 Bar
clean, free from solids or abrasive substances, non aggressive.
IP 68
F
Model:
from 0°C to +40°C
from -10°C to +40°C
falls within the limits envisaged by EC Directive 89/392/EEC and
subsequent modifications.
in accordance with standards CEI 2-3 – CEI 61-69 (EN 60335-2-41)
20
Line fuses (Amps)
1x220-240V 50/60Hz
3x400V 50/60Hz
1x230V 60Hz
6
8
8
10
8
8
10
4
4
4
4
4
4
4

Publicité