Télécharger Imprimer la page

Videotec ULISSE RADICAL Manuel D'instructions page 16

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 81
7.4 Connection of the power
supply line
Depending on the version, the device can be
provided with different power supply voltages. The
power supply voltage is indicated on the product
identification label. (4.2 Product marking, page 8).
Electrical connections must be performed
with the power supply disconnected and
the circuit-breaker open.
When commencing installation make sure
that the specifications for the power supply
for the installation correspond with those
required by the device.
Check that the power supply socket and
cable are adequately dimensioned.
Earth cable should be about 10mm longer
than the other two, so that it will not be
disconnected accidentally if pulled.
The power supply cable must be covered
by the silicone sheath (01) supplied. The
silicone sheath must be fastened with the
corresponding cable tie (02).
N
a
L
Fig. 15
14
CN1
01
02
7.4.1 24Vac power line connection
Cut the cables to the correct length and make the
connections. Connect the power supply to the
terminal: CN1.
24Vac
a
Fig. 16
Connect the power supply cables as described in the
table below.
CONNECTION OF THE POWER SUPPLY LINE
Colour
Power supply 24Vac
Defined by the installer
Defined by the installer
Yellow/Green
Tab. 2
CN1
24Vac
Terminals
24Vac
24Vac
MNVCUPKHXL_2222_EN