8. Technical specifications

Electric Pole-Mounted Pruner IEAS 600
Rated Voltage
Nominal Consumption
No-load Speed n
0
Guide Bar
Variable height adjustment
Working height
Chain speed
Oil
Weight with bar+chain
Chain type
Guide Bar type
Class of Protection
Sound Pressure Level ISO 22868
Vibration ISO 22867
Noise emission information in accordance with the German Product Safety Act (ProdSG) and the EC Machine Direc-
tive: the noise pressure level at the place of work can exceed 80 dB(A). In such cases the operator will require noise
protection (e.g. wearing of ear protectors).
Wear hearing protection. The influence of noise can cause hearing loss.
Attention!
The vibration value will change on the basis of the area of application of the electric tool and may lie above the
specified value in exceptional situations.
- The specified vibration emission value was measured by a standardized test methods and can compare with
other power tools are used.
- The specified vibration emission value can also be necessary for the assessment of work breaks are used.
- The specified vibration emission value can vary during the actual use of the electric tool by specifying the
value, depending on the way how to use the power tool.
- Try to reduce the level of vibrations as much as possible. Appropriate measure for lowering vibration are
wearing work gloves and limiting working time. It is important to observe all parts of the working cycle (e.g.
the time when the power tool is turned off and the time when the power tool is turned on but it is not working
under load).
Keep the development of noise and vibration to a minimum!
• Only use properly functioning machines.
• Maintain and clean the machine regularly.
• Adapt your working method to the machine.
• Do not overstress the machine.
• If necessary, have the machine inspected.
• Switch the machine off when it is not in use.
• Wear work gloves.
Attention: Noise protection! Please observe the local regulations when operating your device.
GB | Operating Instructions
230-240 V ~ / 50 Hz
600 W
4000 min
approx. 200 mm
from 1,85 m to 2,74 m
up to 4 m
7,5 m/s
60 ml
3.4 kg
91PJ033X
080SDEA041
II
84,4 dB(A)
1,758 m/s
8
-1
K = 2,5 dB
2 K = 1,5 m/s
2