Technical data

6.1 General

Supply voltage
Power consumption
Backlight current max.
Reverse battery polarity protection
Dimensions, meter
Dimensions, sensor
Cable length, sensor
Operating temp. meter
Operating temp. sensor
Storage temp. sensor
Weatherproof Sealed
Adjustable backlight
Alarm Output
Resolution, meter
Resolution, sensor
Repeatability
Tilt compensated
Output error
Output change with tilt
Interface options
Bluetooth current max.
NMEA 2000 current max.
The interface options are not user installable.
6.2

Certifications

Maritime Navigational and Radiocommunication
Equipment & Systems
EMC
: Conducted/Radiated Emmission : according to IEC 60945-9
Conducted/Radiated Immunity
Safety
: Dangerous voltage, etc.
Electronic Compass EC
: 10 - 30 Volts DC
: 90 mA @ 12V, 50 mA @ 24V
: 40 mA (extra)
: 110 x 110 x (24.5 + 31.5 mm)
: 72 x 72 x 170 mm)
: 10 m
: -20 to +70 °C
: -20 to +50 °C
: -30 to +70 °C
: according to IP66
: 5 brightness levels, off and external input
: Open collector, max. 100 mA
: 0.5 deg.
: 0.1 deg.
: 1°
: up to 35°
: 2° max.
: 2° max.
: NMEA 0183
(Standard, 4800 baud, up to 19200 selectable)
NMEA 2000 (Optional)
Bluetooth (Class 1)
: 100 mA (extra)
: 100 mA (extra)
: according to IEC 60945
: according to IEC 60945-10
: according to IEC 60945-12