4.1.6 Calibration (ST6)
Magnetic deviation, caused by the vessel
itself, results in incorrect compass readings.
This magnetic deviation can be corrected
by means of the calibration procedure.
• Press
in the default mode to enter
the menu.
• Use the
/
the Calibration menu (ST6).
• Press
to enter the Calibration
menu.
• Use the
/
Auto or Manual.
4.1.6.1 Automatic calibration
The electronic compass has an automatic
calibration procedure. Default 'Auto Cali-
bration' is 'ON'.
The compass sensor will calibrate itself
every time two full circles at a constant
speed have been made within 1 to maxi-
mum 4 minutes per circle.
You can switch this function OFF and use
the manual calibration command.
4.1.6.2 Manual calibration
To calibrate the compass sensor you need
a calm day and a clear area. Start turning
your boat in a large circle at a constant
speed. Then select calibrate in the menu
and press
and
er for two seconds. Now the display shows
the heading and 'In process'. The time to
complete the circle (full 360°) should be at
least 1 up to maximum 4 minutes. When
the calibration was successful the display
shows 'Done' and a short beep will be
heard. Circles may be clockwise or coun-
ter clockwise.
If the circle was not in between the time
limits, the old calibration is restored and
you can see on the display if the circle was
too fast or too slow.
Electronic Compass EC
buttons to select
buttons to select
buttons togeth-
Example:
• Start turning the boat in a large circle.
• Goto menu Calibration and select man-
ual calibration, press
• Press
and
seconds -> In process
• Now continue the circle and wait for the
compas display to beep.
The display now shows if the calibration
was completed or not.
4.1.7 Alignment (ST7)
Alignment error adjustment should be
done by taking a couple of known runs
from a chart and compare the magnetic
heading with the magnetic heading shown
on the display. The difference can be com-
pensated by setting the Align value.
• Press
in the default mode to enter
the menu.
• Use the
/
the Align menu (ST7).
• Press
to enter the Align menu.
• Use the
/
offset. This can be set in steps of 0.1°
up to +/- 99°.
• Press
to return to the main
menu or
• Keep
pressed for two seconds
to exit to the default mode.
ENGLISH
together for 2
buttons to select
buttons to set the
19