Use and maintenance
Inspect the strainer element regularly for
contaminents.
N.B. The lid doesn't need to be removed for
inspection.
Clean the strainer element if dirt has accu-
mulated.
Close the seacock. Unscrew the knurled
knobs and remove the lid of the water
strainer, see drawing 5.
Remove the strainer element out of the
housing and flush the strainer with clean
water.
Re-install the strainer element and reinstall
the lid.
N.B. Secure or loosen the knurled knobs
always manually. Never use tools for this
purpose, see drawing 6 and 7.
Check the seal between lid and housing
after cleaning and re-assembling the strain-
er. An improperly sealed lid will result in air
sucked in by the sea water pump of the
engine which again will result in overheat-
ing of the engine.
Cooling water strainer model 525
www.busse-yachtshop.de | info@busse-yachtshop.de
To prevent damage of the water strainer,
during frost in the winter time, either the
water must be drained or the installation
must be filled with anti-freeze.
Remove the hoses to drain the strainer; the
housing is not equipped with a drain plug.
Take care that during filling with anti-freeze
no anti-freeze is spilled into the waterway.
Anti-freeze is poisonous.
Technical data
Material housing
Material strainer element : Stainless steel
Material lid
Weight
Max. ambient temperature : 75 °C
Max. water temperature
Max. pressure
ENGLISH
ENGLISH
: Stainless steel
: PMMA
: 2,7 kg
: 55 °C
: 0,5 bar
5
3.0503