3. USE OF FAN
B
A
3.9
Programming the Timer
3.9.1
Programmed startup of the fan
The TIMER can be set for any time of the day .
B
Press the TIMER key once.
The display will show the section relating to the clock, together with the
symbol (flashing).
O N
O F F
Set the desired hours and minutes by pressing the corresponding
+
keys.
Press the TIMER ON key to confirm the time setting for the
programmed startup.
The
symbol and the section of the display relating to the clock
O N
O F F
will remain lit.
To cancel the programmed startup, press the TIMER ON key several
times until the
symbol, and the section relating to the clock,
O N
O F F
disappear from the display..
LThe programmed startup time remains memorised; on each new
startup of the fan, the
function can be reactivated (see points 1
O N
to 3) or cancelled (see point 4).
Attention!
The ambient temperature, the fan speed and the operating mode must be
set before the activation of the programmed startup
The signal is automatically sent to the fan; the display will briefly show
B
A
the symbol
.
The TIMER ON operation must be performed with the unit turned off
3.9.2
Programmed startup and shutdown of the fan
The TIMER can be set for any time of the day
Press the TIMER OFF.
The display will show the section relating to the clock and the symbol
flashing.
O N
O F F
Set the desired hours and minutes by pressing the corresponding keys
Press the TIMER OFF button to confirm the set time for the
programmed shutdown.
The symbol
and the display sector relative to the clock will
O N
O F F
remain on.
Press the TIMER OFF button to confirm the set time
programmed shutdown.
The symbol and the display sector relative to the clock will remain
on.
To deactivate the programmed shutdown, press the TIMER OFF
button 1 time until the symbol disappears from the display.
The programmed shutdown time remains stored each time the fan
turns on. The function
O N
O F F
deactivated (see point 4).
Attention!
The ambient temperature, the fan speed and the operating mode must be
set before the activation of the programmed shutdown
The signal is automatically sent to the fan; the display will briefly show
the symbol
.
The TIMER OFF operation must be performed with the unit turned on
48
A
B
A
B
A
O F F
.
O N
O F F
B
A
B
A
for the
O N
O F F
can be reactivated (see point 1 and 3) or
.
O N
O F F
-
3.10 Activating programing "SLEEP " night mode
The SLEEP is default disactivated
Press the SLEEP key to activate the night-time program, the display
will show the symbol
B
A
Press the SLEEP key to activate the night-time program, the display
will show the symbol
increases the preset temperature by 1 °C after 1 hour and by 2 °C
after 2 hours of operation.
With the SLEEP program activated in Heating,
decreases the preset temperature by 1 °C after 1 hour and by 2 °C
after 2 hours of operation, maintaining it for the next three hours of
operation.
To cancel the night-time program, press the SLEEP button
The
symbol will disappear from the display.
Attention!
The signal is automatically sent to the fan; the display will briefly show
the symbol
.
In ventilation operating mode
activated.
B
A
- +
.
B
A
3.10.1 Horizontal adjustment
The horizontal orientation of the air flow is fixed and must be carried
out manually as in figure E
.
or Dehumidification
, mode, the fan
mode, the fan
and
the SLEEP function cannot be
Fig. E