1. GENERAL
Technical Data
Emmeti Models
Refrigerating capacity (1)
Refrigerating capacity
sensible(1)
Refrigerating capacity
latent(1)
Water flow (1)
Loss of charge (1)
Heating capacity (2)
Water flow (2)
Loss of charge (2)
Air flow
Sound Power level
Total electric power input
Max power input
Max current
Power supply
Water quantity coil
Max operating pressure
Dimensions and weight
Dimensions
Weight
Inlet/outlet water connection (3)
Water drainage connection
Water inlet / outlet connec-
tions (3)
Condensate drain connection
1.5 Receiving and handling the product
The fan coils come in single packs protected by a cardboard box.
It is advisable to remove the packaging only when the
appliance has been located near the point of installation.
After the packaging has been removed, the fan coil must
be handled manually by suitably equipped, qualified
personnel and in compliance with accident-prevention
norms and suitable equipment for the weight of the
appliance.
Take care when removing the adhesive strips from the
appliance.
Packaging components must be disposed of correctly and
not left within reach of children since they are a potential
source of danger.
36
SILENCE
kW (max)
kW (med)
kW (min)
kW (max)
P
*
kW (med)
rated,c
kW (min)
kW (max)
P
*
kW (med)
rated,c
kW (min)
l/h (max)
l/h (med)
l/h (min)
kPa (max)
kPa (med)
kW (max)
P
*
kW (med)
rated,h
kW (min)
l/h (max)
l/h (med)
l/h (min)
kPa (max)
kPa (med)
kPa (med)
m
/h (max)
3
m
/h (med)
3
m
/h (min)
3
dB(A) (max)
L
*
dB(A) (med)
WA
dB(A) (min)
kW (max)
P
*
kW (med)
elec
kW (med)
W
A
V/Ph/Hz
l
bar
LxPxH
mm
kg
LxPxH
mm
kg
Ø
inch
Ø
inch
EGWW-0712
EGWW-1012
2,20
2,60
1,90
2,00
1,60
1,70
1,70
1,90
1,55
1,60
1,40
1,45
0,50
0,70
0,35
0,40
0,20
0,25
378
447
327
344
275
292
15
20
12
13
10
11
2,30
2,80
2,00
2,20
1,70
1,90
396
482
344
378
292
327
16
21
13
14
11
12
400
480
340
360
280
300
44
51
42
43
40
40
0,026
0,030
0,024
0,025
0,022
0,023
50
50
0,3
0,3
230/1/50
0,34
0,34
845x180x275
845x180x275
10
10
915x255x355
915x255x355
12,5
12,5
1/2"
5/8"
Note
(1) Cooling: Room air temperature 27 °C d.b. 19 °C w.b. Water inlet
temperature 7 °C Water Dt 5 °C
(2) Heating: Room air temperature 20 °C Water inlet temperature 45 °C
Water Dt 5 °C
(3) Connection exchange left standard
* Information requirements for fan coil units according Regulation (EU)
2016/2281
GB
GB
EGWW-1312
EGWW-1512
3,70
4,10
3,10
3,70
2,80
3,10
2,85
3,20
2,40
2,85
2,20
2,40
0,85
0,90
0,70
0,85
0,60
0,70
636
705
533
636
482
533
45
55
40
45
36
40
4,10
4,50
3,50
4,10
3,20
3,50
705
774
602
705
550
602
46
56
41
46
37
41
700
850
600
700
550
600
54
60
50
54
47
50
0,050
0,055
0,045
0,050
0,040
0,045
60
60
0,4
0,4
0,39
0,39
16
940x200x298
940x200x298
12
12
1010x285x380
1010x285x380
16
16