6.4 Service menu (password required)
To access the Service menu:
-
STOP the door
-
Set DIP5 to ON
-
Enter the PW: button sequence OPEN- OPEN- CLOSE- PARTIAL OPENING
Remove cables from PIN 3, 4, 20 during programming
STEP 1
level options
st
1
MIN BRAKING VOLT. Default 340Vdc
2
MAX BRAKING VOLT. Default 380Vdc Threshold for total intervention of braking resistance
3
OVERCURRENT LIMIT
Default 10A
4
RAMP SLOPE DURING OPENING
5
BATTERY LEVEL
6
ALARM LIST
ONCE PROGRAMMING HAS ENDED, SET DIP5 TO OFF
7. ALARMS
MESSAGE
Ditec
Opening of VBUS IBUS
Door open - automatic closing time Door open
Closing of VBUS IBUS
Input 40 closed; input 8 open
input 40 open; input 8 closed
Limit switches open
Opening safety device activated
Door stopped
Stand by encoder
8. INTERLOCK
Notes
Threshold for partial intervention of braking resistance
If the current on the BUS exceeds the set threshold, the door opens at
half the speed to reduce absorption.
Changes the slope of the deceleration ramp when opening. Default 15.
(If the value is increased, the ramp distance is reduced).
Visualizes the encoder battery charge level from 0% to 100%
The last 50 alarms are displayed: Overcurrent; bus voltage exceeds limit,
Intervention of brake resistance, inverter overtemperature, faulty motor
driver (encoder). To exit, press partial opening
SITUATION
door closed waiting for command
door opening
door closing
intervention of photocell
Primary safety device intervention
(SLEC / SAFETY EDGE)
Intervention of safety microswitch on manual
opening device / intervention of thermal
protection on motor / opening (A) and closure
(C) limit switches simultaneously active.
photocell engaged when door is closed
and door does not open
stop command activated
New control panel power on / replacing
control panel power on
Absolute Encoder not connected.
DOOR 1
INPUT
+24V
1 IN NC C NO
M4
INPUT
Logical
+24V
operation
1 IN NC C NO
- 27 -
ON
1 2 3 4 5 6 7 8
NOTES
When door is moving
When door is moving
Message that only appears if the "safety
in open" function is set to YES on the
advanced menu (step 7).
Control panel already programmed to
work with motor having absolute encoder.
To reset see troubleshooting chapter.
DOOR 2
M4
EN
0DT866 10-05-2022