52E
1. 52E CONTROL PANEL (INVERTER) - Connections
Command
1
2
NC
1
3
NO
1
4
NO
41
40
NC
1
8
NC
1
20
NO
1
11
NC
1
13
NC
1
12
NC
1
9
NO
M2
Safety device / Commands
M3
Position signal
M4
Interlock
M4A
Back
M5
Motor / brake motor
Output
+
1
24V = / 0.5A
-
0
LAMP
200V= / 0.2A
-F
+F
24V = / 0.5A
U W V
230V~ / 6A
M
3 ~
0DT866 10-05-2022
Function
STOP
If on the programming menu (page 15 point 16)
With contact 1-2 enabled, the opening of the contact STOPS the door
Opening
The closure of the contact activates the opening operation.
Closure
The closure of the contact activates the closing operation.
Reversal safety
The opening of the safety contact triggers a reversal of the movement
contact
(reopening) during the closing operation.
Reversal safety
The opening of the safety contact triggers a reversal of the movement
contact
(reopening) during the closing operation.
Partial opening
The closure of the contact activates a partial opening operation of the duration
set with the advanced menu.
The opening of the contact stops the closing operation.
Closing limit switch
Opening limit switch
The opening of the contact stops the opening operation.
Deceleration limit
The opening of the contact activates deceleration during opening.
switch
Closure enabling
In the case of doors with SLEC, the opening of the contact allows the door
with SLEC
to work only when someone is present.
CONTROL PANEL CONNECTORS
Value
Power supply to accessories.
Power supply output for external accessories, including automation status lamps.
Flashing light (FLM).
230 V~
Non-flashing signal (jumper ON on FML).
Activated during opening and closing operations.
Electric motor brake.
or
Automatically set with the choice of door model in the programming menu.
The output is active for the duration of both the opening and closing operations.
Three-phase motor.
INPUTS
Description
J4
OPEN
SAFETY
OUTPUTS
Description
- 16 -
Brake resistance
Auxiliary panel card
Auxiliary safety card