6.2 ADVANCED MENU

The advanced menu allows you to modify the position of the limit switches which have previously been set
and modify the set default parameters.
To access the Advanced Menu:
-
STOP the door
-
Set DIP 2 to ON
"LIM. SWITCH CAL.", the first item in the advanced menu, will appear on the display.
ONCE PROGRAMMING HAS ENDED, SET DIP2 TO OFF
Remove cables from PIN 3, 4, 20 during programming
STEP 1
level options
st
1
Encoder Calibration
2
Photocell excluded
(step present only for
Reset doors)
3
Primary safety device
excluded
4
Automatic closing
(default SI with T= 5 s)
5
Automatic closing time
6
Command mode
7
Opening safety device
8
Interlock
9
Pre-flashing when
opening
(default no)
10
Opening ramp advance
11
Opening speed
in (Hz)
Scrolling
Confirm
2
level options
nd
Closed position
Change value
(1 unit ≅ 3mm)
Change value
(1 unit ≅ 3mm)
YES
NO
Time variant
Impulsive
Man present
INPUT 1-9
YES
NO
NO INTERLOCK
AIRLOCK
INTERLOCK
YES
NO
CHANGE VALUE
(1 unit ≅ 3mm)
CHANGE VALUE
- 25 -
ON
1 2 3 4 5 6 7 8
Notes
The door will move to the desired
position in man present mode and
at low speed. All the positions
(closing, partial opening, opening)
must be set.
By
increasing
the
value,
position of the photocell by-pass is
raised
By
increasing
the
value,
position of the primary safety by-
pass is raised
Option available only if YES has
been selected for point 4).
Value ranging from 0 to 100 sec.
Selecting 1-9: if 1-9 is closed, the
command mode will be impulsive,
if 1-9 is open the command mode
will be "dead man"
If set to YES, the closed door that
receives an opening command
does not open if the photocell is
activated.
AIRLOCK: door 2 opens with ex-
ternal command only if door 1 is
closed.
INTERLOCK: door 2 opens auto-
matically when door 1 has closed
Pre-flashing has a set time of
3 sec.
When the value increases, the
deceleration distance when
opening increases.
The setting of values that are
higher than the default ones
must be assessed according to
door dimensions and operating
conditions.