TROUBLE SHOOTING

Overheated Back-up Batteries
The gate doesn't move when
pressing the button of the transmitter
The transmitting distance is too short
The Flashing light does not work
The leaves suddenly stop during
moving
The leaves does not move or only
move toward one direction
The master gate closes to the end first
and the slave gate stops, which the
opening or closing sequence is not
being operated properly
The gear motors does not run and
the relay is noisy when operating the
gate opening and closing
If any of the above trouble shooting procedure is not solving your problem, please
contact us with no hesitation
Check the wiring connection of the
batteries.
1. Check if LED1 is "ON" once press the
transmitter.
2. Check if the voltage of the batteries is
above 22V.
3. Check if LED2 is "ON" and blinks
accordingly.
4. Make sure all the wiring connections are
firmly connected
to the terminals on the PCB.
5. Make sure the fuse is workable. on the
panel and power socket.
Make sure the connecting terminals of the
Antenna is firm.
Check the battery on the trasmitter.
Check if the wiring connection of the
flashing light is correct.
1. Check if the gate can be moved freely
and no obstacles in between.
2. Make sure the wiring connection of the
gear motors is firm.
3. Make sure the safety beam are operating
properly if installed.
4. Cut off the power of the engine. Release
the motor and make sure the gate can
move freely.
1. Check if the gate can be moved freely
and no obstacles in between.
2. Make sure the wiring connection of the
gear motors is firm.
3. Make sure the fuse is workable.
4. Make sure the safety beam are operating
properly if installed.
5. Cut off the power of the engine. Release
the motor and make sure the gate can
move freely.
Check the condition fuse.