RF1 Remote receive board
RF-Learn
SETTING
SYS-Learn
LED1
LED2
LED3
SWITCH SETTINGS (DIP SWITCH) SW1 : SIET
LED4
OFF
ON
SW1:Set
1. D/S set
2. Over_C1
3. Over_C2
4. Auto
5. Ph
NONE
1 2
Switch settings: «ON» right position, «OFF» left position.
DIP SWITCH 1 :
ON = double gate operation
OFF = single gate operation (connection on 5 and 6)
RX
TX
POWER SETTING DIP SWITCH 2 ET 3
photocellules
DIP SWITCH OVER C1
DIP switch 2 OFF
DIP switch 2 OFF
DIP switch 2 ON
DIP switch 2 ON
GATE AUTO-CLOSE ADJUSTMENT
DIP SWITCH 4
ON: Active automatic closing in 30 seconds. If the transmitter, push button, or the key
selector is activated before the auto-close counting, the gate will close immediately
OFF: Exclude automatic closing
3
4
5
6
bouton
sélecteur
poussoir
à clé
DIP SWITCH OVER C2
Dip switch 3 OFF
Dip switch 3 ON
Dip switch 3 OFF
Dip switch 3 ON
FI
Fusible T20A
250V
7
8
9
10
11 12 13 14
feu
clignotant gâche
M1
CURRENT (AMP)
2.8A
2.1A
1.8A
1.6A
EN ::: 39
EN
M2