Comfort Pure Air™ Bath
Decrease Speed (Cont)
Your air bath is designed to provide different massage experiences based on selected blower intensity. You can
generally expect the following:
Setting 1 –
only the Thermal Lumbar Comfort (TLC) areas (inverted U on backrests) will be active
Setting 2 –
the TLC area and most of the perimeter will be active
Setting 3 –
the TLC area and all of the perimeter will be active
Setting 4 –
all air channels active
Setting 5 –
all air channels active
Purging the Air Bath
The air bath blower will operate for 20-minutes and then automatically shut off to end the bath, unless power is
manually turned off. In either case, twenty minutes after the blower has shut down, the blower will turn ON for a
1-minute drying cycle to blow out any water remaining in the air channel.
If the bath is used without the blower operating (showering or bathing without using the blower), initiate the 1-minute
drying cycle manually by use of the ON/OFF switch. Turn the switch ON and OFF again as you exit the bath and the
drying cycle will occur in twenty minutes.
Daily Purge
To Acitvate:
Holding the (
) button for 5-seconds when the blower is off activates the daily purge. The blower will start every day
at the same time for 1-minute. Once the daily purge is activated, the blower will come on for 1-second, turn off for
two-seconds, come on for 1-second and then turn off.
To Deactivate:
Holding the (
) button for 5-seconds when the blower is off deactivates the daily purge. When the daily purge is
deactivated, the blower will come on for 1-second and then turn off.
Maintenance
To clean your bathtub, simply use a mild, nonabrasive liquid detergent solution. You can protect and restore the gloss
to a dulled acrylic surface by applying Meguiar's #10 Mirror Glaze, a product specifically designed for use on acrylic
finishes. If Meguiar's is not available, use a fine grade automotive rubbing compound followed by an application of
automotive paste wax.
Never use abrasive household cleaners on any Jacuzzi Luxury Bath product.
Surface Repair
Minor scratches which do not penetrate the color finish can be removed by lightly sanding with 600-grit wet/dry
sandpaper. Restore the gloss using Meguiar's Mirror Glaze or automotive paste wax. Major scratches and gouges
which penetrate the acrylic surface will require refinishing. Call Jacuzzi Luxury Bath to find a service agent in your area.
Troubleshooting Procedures
PROBLEM
Blower does not start
Blower operates but air is not exiting all of the holes
Blower shuts off unexpectedly
If the unit is within the warranty period, contact Jacuzzi Whirlpool Bath Service Support at 1-800-288-4002 with your bath's serial number before
work is started. The serial number is located on the Specification/Serial Number Plate.
Installation and Operation
PROBABLE CAUSES
No power to blower
Blower not connected
Blower faulty
Blower intensity is not sufficient
Obstructed air holes
20 minute timer has elapsed
GFCI tripped
Inadequate supply wiring
Improper ventilation
www.jacuzzi.com
REMEDY
Reset GFCI and/or breaker
Ensure plug is fully in outlet
Ensure control panel is connected to control box
Ensure control box is connected to control panel
Contact Jacuzzi Luxury Bath @ 800-288-4002
Increase the blower intensity. NOTE: The system is
designed such that all air channels operate at the 4th
blower setting.
Remove debris with a toothpick or tooth brush
Turn on blower
Reset GFCI. If it continues, to trip, do not use the unit
Consult a licensed electrician to correct
Contact Jacuzzi Luxury Bath @ 800-288-4002
Page 15