Before You
Call For
Service
8
Save time and money! Review the charts on the following pages first and you may not need to
call for service.
Problem

Possible Causes

Fan and lights do
The hood was never electrically
not operate when
connected by the installer/
the switches are
electrician/builder.
turned on
A fuse may be blown or a circuit
breaker tripped.
The blower does not
The blower motor wire harness was
work but the lights do
not connected or was not connected
properly by the installer/electrician/
builder to its mating connector
located inside the hood on the top
surface, to the left of the blower
assembly.
The blower fails
Many factors could be the root
to exhaust the
smoke/steam/odors
Installation could be the problem:
adequately
Your hood was designed to meet
If your duct length exceeds the
manufacturer's requirements, hood
also be reduced if the house duct
work is too small or there are too
many elbows in the system.
Obstruction in duct work could be
the problem.
Damper blade may not be opening.
Damper blade on Wall or Roof Cap
may not be opening.
air is required for exhausting
appliances to operate to rating.

Troubleshooting Tips

Professional Vent Hood
What To Do
Call the electrician/installer/builder to
complete the the installation. This is not
covered by warranty.
Replace the fuse or reset the circuit
breaker.
lock the service disconnecting means
to prevent power from being switched
on accidentally. When the service
disconnecting means cannot be locked,
securely fasten a prominent warning
device, such as a tag, to the service
panel.
wire harness connector. Is it plugged
into its mating connector?
3. If no, plug the blower motor connector
into its mating connector on the top of
the hood. Switch the power back on.
Check to see if the fan now works.
4. If no, check the circuit breaker/fuse.
If it is blown/tripped, replace/reset it.
Does the blower work now? If no, call
Monogram for service.
Contact your installer or builder.
Make sure nothing is blocking the vent
(bird nests or kinks in the duct work).
Make sure the tape is removed from the
damper blades and that it swings open freely.
Contact your builder so they can make
sure the damper swings open freely.
are kept clean of grease and dirt.
problem, call for service.
Check with local building codes, which
may require or strongly advise the use
of makeup air. Visit Monogram.com for
available makeup air solutions.