TLS2 Setup
[500-503] System Setup Close Times Screen
Legend for numbered boxes
This screen allows you to select Auto (Timed) or Manual
(Snapshot) Shift Close times. The default setting is
Timed (close by time).
1
Shift Close Method [500] - touch the Select button to
the right of the window and select Timed (Auto) or
Snapshot (Manual) shift close method. Default is
Timed.
2
Shift Close Timeout [501] - Enabled only if the
Snapshot shift close method is chosen. Touch the
number button to the right of the window and enter
the Timeout.
When the timeout period starting from the last closed
tank shift expires, any unopened tank shifts will
automatically be closed.
For example, Shift Close Timeout is set to 30. You
select manual shift close on tank 3. 30 minutes later
the shift is closed for the remaining tanks, the shift
number increments and a shift report is created. If the
system is setup to autodial on Shift Close Event, the
autodial assigned receiver will be sent the
notification.
Allowable Timeout selections: 30 to 60 minutes.
Default is 30 minutes.
3
Inventory Log Time [502] - Touch the clock button to
select the start time in a 24-hour period you want to
record the first inventory that will be placed in the
16
01-01-2000
ALL FUNCTIONS NORMAL
12:00 AM
SYSTEM SETUP CLOSE TIMES
SHIFT CLOSE METHOD
1
[500]
2
SHIFT CLOSE TIMEOUT
[501]
3
INVENTORY LOG TIME
[502]
INVENTORY LOG INTERVAL
4
[503]
[500-503] System Setup Close Times Screen
SNAPSHOT
30
00:00
Inventory Log.
Default is 00:00 (midnight).
4
Inventory Log Interval [503] - Inventory Log records
will be recorded by the system automatically at the
intervals you select in this field. Touch the down
arrow button to the right of the window and select the
interval.
Allowable intervals: 1 hour, 2 hours, 3 hours, 4 hours,
6 hours, 8 hours, 12 hours, 24 hours, 5 minutes, 10
minutes, 15 minutes, 20 minutes or 30 minutes.
Default is 1 hour.
For example, you select an Inventory Log Time (item
3) of 00:00 (midnight) and you select a 30 minute
Inventory log interval (item 4), then the system will
record inventory snapshots at 00:00 (midnight), 12:30
am, 1:00 am, 1:30 am, etc.. The maximum number or
records in the Inventory Log is 72. The Inventory Log
is a rolling (first in, first out) log of 72 maximum
records.