7. PROBLEMS: CAUSE AND SOLUTION
Below is a table of possible anomalies, their causes and solutions:
PROBLEM
1.Rejects smoke and
/ or insufficient
draught
2. Excessive dirt on
glass
3. Glass bleaching or
colour fading of the
plate
4. Poor heating
5. Venting smoke
and / or gases from
the front, bad smell
6. Excessive draft
7. Poor draft
CAUSE
Incorrect duct
Lack of air supply for combustion
Incorrect position of registers
Incorrect duct
Inappropriate fuel
Overly closed registers
Excessive temperature caused by
excessive heat in the combustion
chamber
Inappropriate fuel
Insufficient load
Combustion control registers in
the wrong position
First lighting
Flammable or combustible items
in the enclosure or surrounding
walls of the equipment
Crack in the combustion chamber
of the equipment
Incorrect duct
Combustion control registers in
the wrong position
Incorrect duct
Duct dirtiness
SOLUTION
Duct servicing*:
-connection
-diameter
-leaks
-insufficient length
-outdoor access
-possible elements blocking the exit
Check vents and / or outside air supply.
Simultaneous operation with other ventilation devices and
/ or heating
Setting the register
Revise section on insufficient flue (below).
Use recommended fuel
Adjust registers
Check the fuel load avoiding overheating
Adjust registers
Use recommended fuel
Adding fuel
Adjust registers
Wait for the polymerization process of the paint to finish;
this can take from one to several lightings.
Review of insulating materials such as fiberglass,
fireproof wood or any inflammable elements and replace
them.
Check for tightness and if you discover a crack, please
contact your dealer.
Duct servicing
- Excessive length
- Check Depression
- Incorrect diameter
- Check door gasket
Open the primary and secondary register following the
steps outlined in the manual. Should this not have an
effect, check that the flue duct is clean; if it is not clean,
contact a professional to clean this. If the problem
persists contact your dealer.
pag. 14

Publicité

Table des Matières
loading

Table des Matières