1
Introduction
We are pleased with your decision to purchase the Waxlectric I or Waxlectric II� This device sets a new
standard with regard to functionality, performance and safety�
1.1
Symbols
In the instructions for use and on the unit itself you will find these symbols with the following meanings:
Danger!
This indicates a direct risk of injury. Consult accompanying documents!
Electrical current
This indicates a risk of hazard due to an electrical current.
Attention
Hot surfaces.
Attention
Disregarding this warning may result in damage to equipment.
Notice
This provides the operator with useful information to improve and ease use.
Only intended for indoor use.
Observe the operating instructions.
The device complies with the requirements of the applicable EU directives.
The device is subject to the EU directive 2002/96/EG (WEEE directive).
► List, particular attention should be paid
• List
- List
⇒ Instructions / appropriate action / input / operational sequence:
You will be asked to carry out the action in a specified order.
Other symbols are explained as they occur�
2
Safety
2.1
Intended Use
The Waxlectric is an electronically controlled wax knife, suitable for practically all modelling and wax-
ing-up applications� It is available in either a one- or a two-channel version� The operating temperature
can be adjusted in 1 °C-increments from 50 °C to 200 °C [in 2 °F-increments from 122 °F to 392 °F]�
However, do not set the temperature too high, as some waxes are very sensitive to overheating�
2.2
Improper Use
Only spare parts and accessories supplied or authorized by Renfert GmbH may be used with this prod-
uct� If other spare parts or accessories are used, this could have a detrimental effect on the safety of the
device, increase the risk of serious injury and lead to damage to the environment or the device itself�
2.3
Ambient Conditions for Safe Operation
The device may only be operated:
• Indoors
• Up to an altitude of 2,000 m above sea level,
• At an ambient temperature of between 5 - 40 ºC [41 - 104 ºF] *),
• At a maximum relative humidity of 80 % at 31 ºC [87�8 ºF], dropping to a linear of up to 50 % relative
humidity at 40 ºC [104 ºF] *),
• With mains power where the voltage fluctuations do not exceed 10 % of the nominal value,
• Under contamination level 2 conditions,
• Under over-voltage category II conditions�
*) Between 5 - 30 ºC [41 - 86 ºF] the device can be operated at a relative humidity of up to 80 %� At temperatures
between 31 - 40 ºC [87�8 - 104 ºF] the humidity must decrease proportionally in order to ensure operational readi-
ness (e�g� at 35 ºC [95 ºF] = 65 % humidity, at 40 ºC [104 ºF] = 50 % humidity)� The device may not be operated at
temperatures above 40 ºC [104 ºF]�
- 3 -
EN