Loosen the bolts on the adjustable
legs and place the carrier into the
wood frame.
Adjust the carrier to the desired
height with reference to the
Finished Floor (see Table 1 for
guide) and marked on the wood
frame.
Tighten the two bolts on the legs
to secure the height of the carrier.
Mark the location for drilling pilot
holes for the screws to secure
the carrier to the wood frame.
There are six (6) screws for the
side (3 on each side) and two on
the feet. Make sure the carrier
before placing the markings.
Remove the carrier from the
wood frame, drill six (6) 1/8"(3mm)
holes on the wall stud (Trimmer/
(plywood); for concrete, drill 3/8"
(10mm) holes for anchors.
For vertical drain installation, clip the upper
bracket to the front slot of the frame as shown.
Drill a 3-3/4"(95mm) hole on the subfloor 1-3/4"
(45mm) from the front of studs.
1-¾"
( 45 )

INSTALLATION PROCEDURE

Installing the In-Wall Tank System
A
A
A
Front Slot
A
A
A
B
B
For left or right drain installa-
tion, clip the upper bracket to
the back slot of the frame as
shown.
Back Slot
4
H
A
Ø 1/8" [3mm]
1
2
B
2
1
45°
Ø 1/8"
[3mm]
45°