ANTI CONDENSATION SWITCH

This appliance has the ability to switch from an electronic intermittent pilot ignition (IPI) to a standing pilot
EN
(ACS) for cold climates. The heat generated by the standing pilot will improve the start up operation on
colder climate days. Therefore we recommend switching to the standing pilot on those colder days. The anti
condensation switch (standing pilot) is located in the control panel. Using your fi nger, fl ip the switch up for
standing pilot, or down for intermittent pilot ignition.
INSTALLER NOTE: Some
jurisdictions may prohibit the
use of a standing pilot. In these
jurisdictions the anti condensation
switch shall be disconnected
to comply with local codes. To
disconnect locate the white
connector at the end of the
white and blue wires of the
ACS switch and disconnect.
W415-1146 / A / 02.16.13